BLI 1500 Incinerator


BLI 1500 Incinerator
 
BLI 1500 Incinerator
   

Specification
U.S Standard Metric System

Length: 131" (139" With Cremation Burner) xm (3.3m with cremation burner)
Width: 68" (82" With Control Panel) 1.7 (2.0m with control panel)
Height:: 84" (96" With Doorcap) 2.1m (2.4m with Doorcap)
Weight: 23,000 lbs. 10,432 Kg
Door Opening:    
Gas Pressure:

Natural Gas 7" W.C.
Propane Gas 11" W.C.
Natural Gas 1.7 kPa W.C.
Propane 2.7 kPa W.C.
Power Requirements: 220V, Single Phase, 30 AMPS  
Incineration Rate: 150 lbs/hour 68 Kg/hour
Weight Capability: 1500 lbs. 680 Kg
Stack Height From Grade:
Minimum 15'
4.5m
Stack Sections: 24" O.D 0.6m O.D
Refractory/Insulation



6" Firebrick Walls
Castable Refractory Lining
(Hearth and Ceiling)
3" 1900 - Board Insulation
0.11m Firebrick Walls
Castable Refractory Lining
(Hearth and Ceiling)
0.07m 1900 - Board Insulation

Chamber Dimensions:



Length: 74"
Width: 54"
Height: 48"
111 Cubic Feet

1.3m
1.8m
1.2m
3.1 Cubic Meters

Burner output:



Maximum Input Rating 2,000,000 BTU's per hour
Afterburner Maximum 1,000,000 BTU's per hour
Modulation Minimum 100,000 BTU's per hour
Cremation Burner 1,000,000 BTU's per hour
2,110,000 KJ per hour
1,055,000 KJ per hour
105,500 KJ per hour
1,055,000 KJ per hour
Air Requirements:


Outside air inlet louvers in the room
located at or below burner height, capable
of passing 2,500 CFM of free air.
Outside air inlet louvers in the room located at or below burner height, capable of passing 1.173 Cubic meters per second
     

Features to the above unit

FULLY AUTOMATIC CONTROL SEQUENCE. Operation is made simple by the fully automatic control sequence. A microprocessor temperature controller, with a digital readout, ensures optimum control while providing the lowest fuel consumption. Visual verification of each stage is provided on the control panel. Operator override is achieved at a turn of a switch for semi-manual control.
MULTI-CHAMBER AIR CONTROLLED DESIGN. The entire combustion process is completed within the air controlled chambers eliminating burning in the stack, allowing for 24 hour operation and providing for greater fuel efficiency over excess air designs.
POLLUTION MONITORING & CONTROL SYSTEM. This system constantly monitors the stack gases to prevent visible emissions. Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically.
REFRACTORY LINED STACK. A three inch insulating liner is provided as a safety feature. While gases seldom exceed 1000°F, the liner reduces heat penetration under every condition, preventing the possibility of fire. A ten year warranty is offered on the stack liner.
LOW NOISE. The secondary combustion blower has been manufactured and installed to allow for low noise operation.