Translation

BLI 400 M4 Animal Incinerator


 
Incinerator Manufacturer, incinerators
Incinerator Manufacturer, incinerators
We have customized our popular BLI 400 model to be able to perform up to 4 separate cremations simultaneously, thereby lowering fuel consumption considerably. Each compartment has its own burner, timer and entry/exit door. Maximum load of each compartment is 35 pounds.
   

Specification
U.S Standard Metric System

Length: 106" (130" With Cremation Burner) 2.7m (3.3m with cremation burner)
Width: 54" (70" With Control Panel) 1.3m (1.7m with control panel)
Height: 74" (86" With Afterburner) 1.5m (1.8m with afterburner)
Weight: 17,500 lbs. 7,937 Kg
Door Opening:    
Gas Pressure:

Natural Gas 7" W.C.
Propane Gas 11" W.C.
 
Power Requirements: 110V, Single Phase, 30 AMPS  
Incineration Rate: 75 lbs/hour 34 Kg/hour
Weight Capability: 400 lbs 181 Kg
Stack Height From Grade:
Minimum 15'
4.5m
Stack Sections: 20" O.D 0.4m O.D
Refractory/Insulation



4 1/2" Firebrick Walls
Castable Refractory Lining
(Hearth and Ceiling)
3" 1900 - Board Insulation
0.11m Firebrick Walls
Castable Refractory Lining
(Hearth and Ceiling)
0.07m 1900 - Board Insulation

Chamber Dimensions:



Length: 24"
Width: 16"
Height: 24"
5.33 Cubic Feet /Per Chamber

0.62m
0.41m
0.62m
0.157604 Cubmic Meters /Per Chamber

Burner output:



Maximum Input Rating 750,000 BTU's per hour
Afterburner Maximum 400,000 BTU's per hour
Modulation Minimum 100,000 BTU's per hour
Cremation Burner 350,000 BTU's per hour
791,250 KJ per hour
422,000 KJ per hour
105,500 KJ per hour
369,250 KJ per hour
Air Requirements:


Outside air inlet louvers in the room
located at or below burner height, capable
of passing 2,500 CFM of free air.
Outside air inlet louvers in the room located at or below burner height, capable of passing 1.173 Cubic meters per second
     

Features to the above unit - Fuel, Oil, Specfications & information on request

FULLY AUTOMATIC CONTROL SEQUENCE. Operation is made simple by the fully automatic control sequence. A microprocessor temperature controller, with a digital readout, ensures optimum control while providing the lowest fuel consumption. Visual verification of each stage is provided on the control panel. Operator override is achieved at a turn of a switch for semi-manual control.
MULTI-CHAMBER AIR CONTROLLED DESIGN. The entire combustion process is completed within the air controlled chambers eliminating burning in the stack, allowing for 24 hour operation and providing for greater fuel efficiency over excess air designs.
POLLUTION MONITORING & CONTROL SYSTEM. This system constantly monitors the stack gases to prevent visible emissions. Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically.
REFRACTORY LINED STACK. A three inch insulating liner is provided as a safety feature. While gases seldom exceed 1000°F, the liner reduces heat penetration under every condition, preventing the possibility of fire. A ten year warranty is offered on the stack liner.
LOW NOISE. The secondary combustion blower has been manufactured and installed to allow for low noise operation.