Translation

BLP 1000 M10 (Multiple Chamber) Pet Crematory


 
animal crematory, pet crematory
CE Crematory

UL Crematory

animal crematory, pet crematory
The B&L Cremation Systems animal crematory BLP 1000 M10 is designed for large Veterinarian facilities, cremating multiple carcasses with a maximum load size of 1000 lbs.
   
multiple chamber crematory  
This design allows for multiple private cremations without co-mingling any remains, up to ten private cremations without any cremain pans required. Still just as fuel efficient because of the hot hearth design, this machine excels with the technology we still use today.

The Primary chamber is divided into ten sections. Two sections are  38" x 18" openings loaded thru a hydraulic loading door located on each the side of the retort. The other eight sections of the machine are the loaded thru manual hinged doors that are also located on each side of the retort.
“Custom designs are available”.


Specification
U.S Standard Metric System

Length: 262" with control panel  
Width: 101" with doors  
Height: 90"  
Weight: 52,000 lbs. 23,600 Kg
Door Opening:

2 doors @ 38" x 18"
8 doors @ 20" x 18"
 
Gas Pressure:

5,000,000 btuh @ 11" WC  
Power Requirements:

230 VAC 60HZ 65 amps
120 VAC 60HZ 10 amps
 
Cremation Rate: - lbs/hour 113 Kg/hour
Body Weight Capability: 1,000 lbs 453 Kg
Stack Height From Grade:
Minimum 18'
5.4m
Stack Sections: 36" O.D x 5'  

Chamber Dimensions:



Length:
Width:
Height:



Burner output:



Maximum Input Rating 5,000,000 BTU's per hour
Afterburner Maximum 1,500,000 BTU's per hour
Modulation Minimum 100,000 BTU's per hour
10 Cremation Burners @ 000,000 BTU's per hour
2,373,875 KJ per hour
1,055,055 KJ per hour
105,505 KJ per hour
791,291 KJ per hour
Air Requirements:


Outside air inlet louvers in the room located at or below burner height, capable of passing 2,500 CFM of free air. Outside air inlet louvers in the room located at or below burner height, capable of passing 1.173 Cubic meters per second
     
 

Features to the above unit

FULLY AUTOMATIC CONTROL SEQUENCE. Operation is made simple by the fully automatic control sequence. A microprocessor temperature controller, with a digital readout, ensures optimum control while providing the lowest fuel consumption. Visual verification of each stage is provided on the control panel. Operator override is achieved at a turn of a switch for semi-manual control.
HOT HEARTH DESIGN. First introduced by B&L, this design allows for wasted afterburning heat to be recycled through the floor, eliminating fluid problems, lowering fuel consumption and extending the hearth life.
MULTI-CHAMBER AIR CONTROLLED DESIGN. The entire combustion process is completed within the air controlled chambers eliminating burning in the stack, allowing for 24 hour operation and providing for greater fuel efficiency over excess air designs.
POLLUTION MONITORING & CONTROL SYSTEM. This system constantly monitors the stack gases to prevent visible emissions. Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically.
REFRACTORY LINED STACK. A three inch insulating liner is provided as a safety feature. While gases seldom exceed 1000°F, the liner reduces heat penetration under every condition, preventing the possibility of fire. A ten year warranty is offered on the stack liner.
LOW NOISE. The secondary combustion blower has been manufactured and installed to allow for low noise operation.