Translation

BLP 200 M3 Pet Crematory


 
animal crematory, pet crematory
CE Crematory

UL Crematory

m3 crematory
   
Made In The United States of America
The B&L Cremation Systems, Inc. BLP 200 M3 pet & animal crematory is designed for small to medium Veterinary facilities, For multiple, individual cremations or a maximum load size of 250 lbs.

This design allows for multiple private cremations without co-mingling any remains, up to three private cremations without any cremain pans required. Still just as fuel efficient because of the hot hearth design, this machine excels with the technology we still use today.
Multiple Chamber Crematory
     

Specification
U.S Standard Metric System

Length: 95" 2.4m
Width: 62" (72" With Control Panel) 1.5m (1.8m With Control panel)
Height: 84" (96" With Doorcap) 2.1m (2.4m With Doorcap)
Weight: 16,000 lbs. 7,257 Kg
Door Opening: 38" W x 26 H" 0.96m W x 0.66m H
Gas Pressure:

Natural Gas 7" W.C.
Propane Gas 11" W.C.
Natural Gas 1.7 kPa W.C.
Propane 2.7 kPa W.C.
Power Requirements:

220V, Single Phase, 60 Cycle, 30 AMPS &
110V, Single Phase 60 Cycle, 10 AMPS
 
Cremation Rate: 75 lbs/hour 34 Kg/hour
Body Weight Capability: 200 lbs  
Stack Height From Grade:
Minimum 17.6'
5.3m
Stack Sections: 18" O.D 0.4m O.D

Chamber Dimensions:



Length: 50"
Width: 38"
Height: 32"
35 Cubic Feet

1.27m
0.96m
0.81m
0.987552 Cubic Meters

Burner output:



Maximum Input Rating 1,100,000 BTU's per hour
Afterburner Maximum 800,000 BTU's per hour
Modulation Minimum 100,000 BTU's per hour
Cremation Burner 300,000 BTU's per hour
1,160,561 KJ per hour
844,044 KJ per hour
105,505 KJ per hour
316,516 KJ per hour
Air Requirements:


Outside air inlet louvers in the room located at or below burner height, capable of passing 2,500 CFM of free air. Outside air inlet louvers in the room located at or below burner height, capable of passing 1.173 Cubic meters per second
     

Features to the above unit

FULLY AUTOMATIC CONTROL SEQUENCE. Operation is made simple by the fully automatic control sequence. A microprocessor temperature controller, with a digital readout, ensures optimum control while providing the lowest fuel consumption. Visual verification of each stage is provided on the control panel. Operator override is achieved at a turn of a switch for semi-manual control.
HOT HEARTH DESIGN. First introduced by B&L, this design allows for wasted afterburning heat to be recycled through the floor, eliminating fluid problems, lowering fuel consumption and extending the hearth life.
MULTI-CHAMBER AIR CONTROLLED DESIGN. The entire combustion process is completed within the air controlled chambers eliminating burning in the stack, allowing for 24 hour operation and providing for greater fuel efficiency over excess air designs.
POLLUTION MONITORING & CONTROL SYSTEM. This system constantly monitors the stack gases to prevent visible emissions. Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically.
REFRACTORY LINED STACK. A three inch insulating liner is provided as a safety feature. While gases seldom exceed 1000°F, the liner reduces heat penetration under every condition, preventing the possibility of fire. A ten year warranty is offered on the stack liner.
LOW NOISE. The secondary combustion blower has been manufactured and installed to allow for low noise operation.