Translation

BLP 500 M3 Pet Crematory


 
multiple chamber
CE Crematory

UL Crematory

The B&L Cremation Systems, Inc. BLP 500 M3 pet & animal crematory is designed for medium Veterinary facilities, For individual cremation or a maximum load size of 500 lbs.

This design allows for multiple private cremations without co-mingling any remains, up to three private cremations without any cremain pans required. Still just as fuel efficient because of the hot hearth design, this machine excels with the technology we still use today.

The Primary chamber is divided into 3 sections. Section A is loaded thru a hydraulic loading door located on the front of the retort. Section B and Section C are loaded thru manual hindged doors and are located on each side of the retort.
Multiple Chamber Crematory
     

Specification
U.S Standard Metric System

Length: 132" 3.5m
Width: 66" (76" With Control Panel) 1.6m (1.9m With Control panel)
Height: 96" (101" With Doorcap) 2.4m (2.5m With Doorcap)
Weight: 20,500 lbs. 9,071 Kg
Door Opening: 40" W x 27 H" 1.01m W x 0.68m H
Gas Pressure:

Natural Gas 7" W.C.
Propane Gas 11" W.C.
Natural Gas 1.7 kPa W.C.
Propane 2.7 kPa W.C.
Power Requirements:

220V, Single Phase, 60 Cycle, 30 AMPS &
110V, Single Phase 60 Cycle, 10 AMP
 
Cremation Rate: 150 lbs/hour 68 Kg/hour
Body Weight Capability: 500 lbs 226 Kg
Stack Height From Grade:
Minimum 18'
5.4m
Stack Sections: 24" O.D 0.6m O.D

Chamber Dimensions:












Section A: (Front)
Length: 39"
Width: 40"
Height: 32"
Section B:
Length: 32"
Width: 17"
Height: 32"
Section C:
Length: 32"
Width: 17"
Height: 32"

Section A: (Front)
Length: 99.06 cm
Width: 101.60 cm
Height: 81.28 cm
Section B:
Length: 81.28 cm
Width: 43.18 cm
Height: 81.28 cm
Section C:
Length: 81.28 cm
Width: 43.18 cm
Height: 81.28 cm


Burner output:






Maximum Input Rating 1,850,000 BTU's per hour
Afterburner Maximum 1,850,000 BTU's per hour
Modulation Minimum 100,000 BTU's per hour
Cremation Burner(s):
2 At 125,000 and 1 At 250,000 BTU's per hour


1,951,853 KJ per hour
1,951,853 KJ per hour
105,505 KJ per hour
Cremation Burner(s):
2 At 131,881 KJ per hour and 1 At 263,763 KJ per hour

Air Requirements:


Outside air inlet louvers in the room located at or below burner height, capable of passing 2,500 CFM of free air.

Outside air inlet louvers in the room located at or below burner height, capable of passing 1.173 Cubic meters per second
     

Features to the above unit

FULLY AUTOMATIC CONTROL SEQUENCE. Operation is made simple by the fully automatic control sequence. A microprocessor temperature controller, with a digital readout, ensures optimum control while providing the lowest fuel consumption. Visual verification of each stage is provided on the control panel. Operator override is achieved at a turn of a switch for semi-manual control.
HOT HEARTH DESIGN. First introduced by B&L, this design allows for wasted afterburning heat to be recycled through the floor, eliminating fluid problems, lowering fuel consumption and extending the hearth life.
MULTI-CHAMBER AIR CONTROLLED DESIGN. The entire combustion process is completed within the air controlled chambers eliminating burning in the stack, allowing for 24 hour operation and providing for greater fuel efficiency over excess air designs.
POLLUTION MONITORING & CONTROL SYSTEM. This system constantly monitors the stack gases to prevent visible emissions. Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically.
REFRACTORY LINED STACK. A three inch insulating liner is provided as a safety feature. While gases seldom exceed 1000°F, the liner reduces heat penetration under every condition, preventing the possibility of fire. A ten year warranty is offered on the stack liner.
LOW NOISE. The secondary combustion blower has been manufactured and installed to allow for low noise operation.