| Translation |
|
||||||||||||||||||||
Specification |
U.S Standard | Metric System | ||||||||||||||||||
| Length: | 150" | 3.8m | ||||||||||||||||||
| Width: | 66" (76" With Control Panel) | 1.6m (1.9mWith Control panel) | ||||||||||||||||||
| Height: | 96" (101" With Doorcap) | 2.4m (2.5m With Doorcap) | ||||||||||||||||||
| Weight: | 23,500 lbs. | 11,113 Kg | ||||||||||||||||||
| Door Opening: | 38" W x 29 H" | 1.37m W x 0.99m H | ||||||||||||||||||
| Gas Pressure: |
Natural Gas 7" W.C. Propane Gas 11" W.C. |
Natural Gas 1.7 kPa W.C. Propane 2.7 kPa W.C. |
||||||||||||||||||
| Power Requirements: |
220V, Single Phase, 60 Cycle, 30 AMPS & 110V, Single Phase 60 Cycle, 10 AMPS |
|||||||||||||||||||
| Cremation Rate: | 150 lbs/hour | 68 Kg/hour | ||||||||||||||||||
| Body Weight Capability: | 750 lbs | |||||||||||||||||||
| Stack Height From Grade: |
Minimum 18' |
5.4m |
||||||||||||||||||
| Stack Sections: | 24" O.D | 0.6m O.D | ||||||||||||||||||
Chamber Dimensions: |
Length: 94" |
2.38m 1.01m 0.8m 1.92304 Cubic Meters |
||||||||||||||||||
Burner output: |
Maximum Input Rating 1,100,000 BTU's per hour Afterburner Maximum 800,000 BTU's per hour Modulation Minimum 100,000 BTU's per hour Cremation Burner 300,000 BTU's per hour |
1,160,561 KJ per hour 844,044 KJ per hour 105,505 KJ per hour 316,516 KJ per hour |
||||||||||||||||||
| Air Requirements: |
Outside air inlet louvers in the room located at or below burner height, capable of passing 2,500 CFM of free air. |
Outside air inlet louvers in the room located at or below burner height, capable of passing 1.173 Cubic meters per second | ||||||||||||||||||
Features to the above unit |
||||||||||||||||||||
| FULLY AUTOMATIC CONTROL SEQUENCE. Operation is made simple by the fully automatic control sequence. A microprocessor temperature controller, with a digital readout, ensures optimum control while providing the lowest fuel consumption. Visual verification of each stage is provided on the control panel. Operator override is achieved at a turn of a switch for semi-manual control. | ||||||||||||||||||||
| HOT HEARTH DESIGN. First introduced by B&L, this design allows for wasted afterburning heat to be recycled through the floor, eliminating fluid problems, lowering fuel consumption and extending the hearth life. | ||||||||||||||||||||
| MULTI-CHAMBER AIR CONTROLLED DESIGN. The entire combustion process is completed within the air controlled chambers eliminating burning in the stack, allowing for 24 hour operation and providing for greater fuel efficiency over excess air designs. | ||||||||||||||||||||
| POLLUTION MONITORING & CONTROL SYSTEM. This system constantly monitors the stack gases to prevent visible emissions. Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically. | ||||||||||||||||||||
| REFRACTORY LINED STACK. A three inch insulating liner is provided as a safety feature. While gases seldom exceed 1000°F, the liner reduces heat penetration under every condition, preventing the possibility of fire. A ten year warranty is offered on the stack liner. | ||||||||||||||||||||
| LOW NOISE. The secondary combustion blower has been manufactured and installed to allow for low noise operation. | ||||||||||||||||||||