| Translation |
|
||||||||||||||||||||
Specification |
U.S Standard | Metric System | ||||||||||||||||||
| Length: | 156" | 3.9m | ||||||||||||||||||
| Width: | 72" (84" With Control Panel) | 1.8m (2.1m With Control panel) | ||||||||||||||||||
| Height: | 96" (104" With Doorcap) | 2.4m (2.6m With Doorcap) | ||||||||||||||||||
| Weight: | 32,000 lbs. | 14, 514 Kg | ||||||||||||||||||
| Door Opening | 46" W x 32" H | 1.1m W x 0.8 H | ||||||||||||||||||
| Clean Out Door: | 21.750" x 19.750" | 0.53m x 0.48m | ||||||||||||||||||
| Gas Pressure: |
Natural Gas 7" W.C. Propane Gas 11" W.C. |
Natural Gas 1.7 kPa W.C. Propane 2.7 kPa W.C. |
||||||||||||||||||
| Power Requirements: |
220V, Single Phase, 30 AMPS (Available In 3 phase & 50 cycle options) 110V, Single Phase, 10 AMPS |
|||||||||||||||||||
| Cremation Rate: | 150 lbs/hour | 68 Kg/hour | ||||||||||||||||||
| Body Weight Capability: |
1,000 lbs. |
453 Kg |
||||||||||||||||||
| Stack Height From Grade: |
Minimum 18' |
5.4m |
||||||||||||||||||
| Stack Sections: | 24" O.D | 0.6m O.D | ||||||||||||||||||
Chamber Dimensions: |
Length: 100" |
2.5m 1.1m 0.9m 2.475 Cubic Meters |
||||||||||||||||||
Burner output: |
Maximum Input Rating 1,500,000 BTU's per hour Afterburner Maximum 1,000,000 BTU's per hour Modulation Minimum 100,000 BTU's per hour Ignition Burner 300,000 BTU's per hour Cremation Burner 500,000 BTU's per hour |
1,582,500 KJ per hour 1,055,055 KJ per hour 105,500 KJ per hour 316,500 KJ per hour 527,500KJ per hour |
||||||||||||||||||
| Air Requirements: |
Outside air inlet louvers in the room located at or below burner height, capable of passing 2,500 CFM of free air. |
Outside air inlet louvers in the room located at or below burner height, capable of passing 2,500 CFM of free air. |
||||||||||||||||||
Features to the above unit |
||||||||||||||||||||
| FULLY AUTOMATIC CONTROL SEQUENCE. Operation is made simple by the fully automatic control sequence. A microprocessor temperature controller, with a digital readout, ensures optimum control while providing the lowest fuel consumption. Visual verification of each stage is provided on the control panel. Operator override is achieved at a turn of a switch for semi-manual control. | ||||||||||||||||||||
| HOT HEARTH DESIGN. First introduced by B&L, this design allows for wasted afterburning heat to be recycled through the floor, eliminating fluid problems, lowering fuel consumption and extending the hearth life. | ||||||||||||||||||||
| MULTI-CHAMBER AIR CONTROLLED DESIGN. The entire combustion process is completed within the air controlled chambers eliminating burning in the stack, allowing for 24 hour operation and providing for greater fuel efficiency over excess air designs. | ||||||||||||||||||||
| POLLUTION MONITORING & CONTROL SYSTEM. This system constantly monitors the stack gases to prevent visible emissions. Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically. | ||||||||||||||||||||
| REFRACTORY LINED STACK. A three inch insulating liner is provided as a safety feature. While gases seldom exceed 1000°F, the liner reduces heat penetration under every condition, preventing the possibility of fire. A ten year warranty is offered on the stack liner. | ||||||||||||||||||||
| LOW NOISE. The secondary combustion blower has been manufactured and installed to allow for low noise operation. | ||||||||||||||||||||
| HYDRAULIC LOADING DOOR. Push button operated, this feature enables the operator to open the door to the desired height from the control panel, an important safety feature for busy installations, providing better fuel efficiency and longer refractory life. | ||||||||||||||||||||
| STAINLESS STEEL FRONT.** More than just aesthetics. Stainless steel is easy to clean, while providing a professional finish to your equipment...an important feature when considering a viewing. | ||||||||||||||||||||
| REMAINS REMOVAL SYSTEM.** A separate remains removal door, located on the side of the unit, is included to enable the operator to push the remains to the rear of the chamber, reducing heat loss and thermal shock as the loading door needs only to be opened 6"- 8" for removal. A stainless steel cooling pan is located on the outside of the unit to prevent fluid contamination. | ||||||||||||||||||||
| REFRACTORY. Our exclusive features are high duty refractory walls in all chambers and six inch 3000°F high duty brick in all non-insulating areas. The hearth is cast from 3000°F abrasive resistant material and the main chamber ceiling is insulating firebrick to provide longevity and better fuel efficiency. | ||||||||||||||||||||
INSTALLATION. Installation is made easy as our units are fully piped, wired and tested prior to shipment from the factory. Once the machine has been off loaded and the stack and utilities hooked-up, out factory personnel provide a free start-up and training service. |
||||||||||||||||||||
| ** = Optional Features at additional costs | ||||||||||||||||||||